The exchanger is used to heat network water with the possibility of deep cooling of the condensate.
Power Industry
Heat exchanger for power plant
Allowable temperature:
Tube side
140 oC
Shell side
204 oC
Allowable pressure:
Tube side
20 bar
Shell side
16 bar
| Client | power and heating plant |
| Media | steam/ water |
| Location | Norway |
| Year | 2021 |
Key parameters:
Mass
4770
kg
Heat Transfer Area
164,7
m2
Materials:
| Tubes and tubesheet | stainless steel1.4404 |
| Shell | carbon steel P265GH |