Post-rip water cooler

Hexonic - Post-rip water cooler

Designed and manufactured by us heat exchanger acts as a post-rip water cooler in the refinery installation.

 

Petrochemical Industry
Petrochemical Industry
Post-rip water cooler

Allowable temperature:

Tube side
130 oC
Shell side
150 oC

Allowable pressure:

Tube side
5 bar
Shell side
13,8 bar
Client refinery
Media acid water / post-rip water
Location Poland
Year 9/2017

Key parameters:

Mass
5630
kg
Heat Transfer Area
103
m2

Materials:

Tubes stainless steel 1.4404
Shell stainless steel with carbon steel cladding