Designed and manufactured by us heat exchanger acts as a post-rip water cooler in the refinery installation.
Petrochemical Industry
Post-rip water cooler
Allowable temperature:
Tube side
130 oC
Shell side
150 oC
Allowable pressure:
Tube side
5 bar
Shell side
13,8 bar
Client | refinery |
Media | acid water / post-rip water |
Location | Poland |
Year | 9/2017 |
Key parameters:
Mass
5630
kg
Heat Transfer Area
103
m2
Materials:
Tubes | stainless steel 1.4404 |
Shell | stainless steel with carbon steel cladding |